COSMO 4N35 PDF

E absolute maximum ratings at 25°C free-air temperature (unless otherwise noted)†. Input-to-output peak voltage (8-ms half sine wave): 4N kV. standard single channel phototransistor couplers. These families include the 4N35, 4N36, 4N37, 4N38 couplers. Each optocoupler consists of. Cosmo 4n35 optoisolator for DC voltage measuring. Hi all, I’ve encountered a problem. I’ve tried to set the input current to the opto by using 5V.

Author: Taubar Meztihn
Country: Guyana
Language: English (Spanish)
Genre: Personal Growth
Published (Last): 3 January 2012
Pages: 366
PDF File Size: 9.19 Mb
ePub File Size: 7.53 Mb
ISBN: 477-2-34797-720-7
Downloads: 60662
Price: Free* [*Free Regsitration Required]
Uploader: Samuktilar

AF modulator in Transmitter what is the A? Cosmo 4n35 optoisolator for DC voltage measuring What voltage range are you trying to measure? Input port and input output port declaration in top module 2.

Looking for a sensor for measuring V AC 9. I don’t mind if the output voltage is not same as the input, but if it’s proportional, I can mend the voltage reading by inserting a constant in the microcontroller. Cosmo 4n35 optoisolator for DC voltage measuring I can only guess at your circuit. Vosmo can the power consumption for computing be reduced for energy harvesting? Cosom Technology file 1. I’ve tried to set the input current to the opto by using 5V and ohm resistor, resulting less than 10mA input current.

Losses in inductor of a boost converter 9. PV charger battery circuit 4. If you have a high voltage available to drive the LED then the accuracy will improve although you will dissipate more power in the LED drive resistor. If you reduce the input voltage the output voltage will increase. I guess there’s no substitute for the hcpl eh?

  BOX SCALE PENTATONICHE PDF

Distorted Sine output from Transformer 8. Cosko will only work for input voltages high enough to turnt he LED on and it will be temperature sensitive though, so it is a very crude option. Cosmo 4n35 optoisolator for DC voltage measuring Hi Keith, here is my circuit, Post added at Another option is to use a micro which has 8 adc inputs measure it and send it thro the opto.

If that cosmoo make coso then maybe it will help to post your circuit, Keith. Turn on power triac – proposed circuit analysis 0.

So, when you reduce the input voltage the LED current will reduce so the collector voltage will increase because the voltage drop in the 1k will reduce due to the reduced collector current. Digital multimeter appears to have measured voltages lower than expected. Opto 4n35 for voltage sensing?

Choosing IC with EN signal 2. The reason I wanted to put optoisolators because the project will interface with a 11kV switchgear.

IC 4N35 Optocoupler

I think I will just let the ADC port get the signals directly from the contacts. Heat sinks, Part 2: I need to use 8 pieces lol.

So you circuit is working correctly – although maybe not how you want it to. It’s just a prototype.

HOT NEW IC 4N35 F4N35 4N 35 COSMO SOP6

In other words, plot the output voltage against input voltage and use the micro to correct for it. Hierarchical block is unconnected 3. How do you get an MCU design to market quickly? Stepped down to 5V of course!

Cosmo 4n35 optoisolator for DC voltage measuring

Is there any cheap optoisolator that you guys can recommend? Dec 242: Cosmo 4n35 optoisolator for DC voltage measuring What you have will be inversely proportional which would be fine – it can be sorted out in software – except that if you were hoping to measure input voltage in that way you will fail because of the non-linear relationship between the LED current and voltage.

  DODFMR 7A PDF

On the output side, I have put the voltage to 5V and resistor as 1k. What is the function of TR1 in this circuit 3. Cosmo 4n35 optoisolator for DC voltage measuring Hurm Equating complex number interms of the other 6.

It outputs fine, however, when I decrease the input voltage the output voltage increases. Cosmo 4n35 optoisolator for DC voltage measuring.

4N35 Optcoupler | 4N35 Datasheet

If you feel cosmp timers and 4n35’s too much, you can use one timer and an opto and multiplex the input of timer. Cosmo 4n35 optoisolator for DC voltage measuring Yes, that is what I thought.

Originally Posted by Iman But it is quite expensive at 11usd per unit.

Originally Posted by nandhu How reliable is it? But I think it would be complicated as I would need 8 dosmo and 8 4n35 for my project. Part and Inventory Search. Cosmo 4n35 optoisolator for DC voltage measuring I see. I am not sure it would be much simpler than using a to turn it into a pulse train though.