DRAGER POLYTRON 3000 MANUAL PDF

View and Download Dräger Polytron instructions manual online. Transmitters for electrochemical sensors. Polytron Transmitter pdf manual download. View and Download Dräger Polytron instructions for use manual online. ( approved as type P3S). Transmitter for electrochemical Sensors. Polytron The Dräger Polytron® is an intrinsically safe gas detector for the continuous The Polytron consists of two components, the docking station, . Please note – Product designs and specifications are subject to change without notice.

Author: Mugor Zulkihn
Country: Sudan
Language: English (Spanish)
Genre: Software
Published (Last): 19 September 2004
Pages: 413
PDF File Size: 9.69 Mb
ePub File Size: 9.60 Mb
ISBN: 114-5-18976-204-8
Downloads: 78803
Price: Free* [*Free Regsitration Required]
Uploader: Daisida

Also See for Polytron Instructions for use manual – 52 pages. Also See for Polytron Instructions manual – 68 pages.

DRäGER POLYTRON INSTRUCTIONS MANUAL Pdf Download.

Designed for the industrial use, the You can configure up to 16 measuring channels. After inserting the sensor, the system is ready for operation. Wide range of applications With its exceptional electromagnetic compatibility and a variety of mounting options, the CE marked Polytron is suitable for many different areas of application ranging from chemical to the semiconductor industries. This current is proportional to the gas concentration.

Shorten the shield if installed to prevent short-circuiting: Set maintenance switch to maintenance position, see page Easy to operate and maintain The operation and maintenance of the Polytron is easy. Maintenance Maintenance Maintenance Maintenance intervals Before starting operation: Page 18 Maintenance 1 Set maintenance switch to left-hand position.

Installing the transmitter Installing the docking station — If the transmitter is to be installed in a Zone 2 explosion-hazard area, select a location with low exposure to mechanical risk. Page 36 ATEX approval The Drager Polytron is an intrinsically safe gas detector for the continuous monitoring of more than 60 toxic gases and oxygen in ambient air. Page 29 ATEX approval The user is responsible for determining the suitability of this product.

  GLEITMO 595 PDF

Link will take you to our database for technical documentation where you can find multilingual documents for download.

Polytron 3000

It uses a high Splash guard 68 07 Splash guard AC sensor 68 09 Notes on use in zone Page 39 ATEX approval Polytron Docking station, one per transmitter Duct Mount Kit Cut excess wires short or 2 Fasten in 4-pin terminal. If preferred, the sensor can be field calibrated in the transmitter. Keison Global trading as: United Arab Emirates E: Also suitable for continuous use in connection with a sampling unit. Intended Use For further poyltron, see the installation notes.

Item Description Order Information Documents Simple, quick installation The Polytron consists of two components, the docking station, for mechanical and electrical installation, and the Polytron transmitter. Page 23 Order No. With its exceptional electromagnetic compatibility and a variety of mounting options, the CE marked Polytron is suitable for many different areas of application ranging from chemical to the semiconductor industries.

Polytron Use only a 5 mm Allen key without a ball head. Page 46 Declaration of Conformity Page 32 ATEX approval The docking station can be mounted and wired in advance, guarded against rain and dust by a modular cover until time of commissioning.

  MALAHOV LUNARNI KALENDAR PDF

The Drager Polytron is available with or without display, in over 60 versions for different gases and set ranges. Fitting The Sensor 2 Open the front cover of the service port with an Allen key by turning anticlockwise approx. Don’t show dragee this message again.

Installing The Docking Station Installing the transmitter Installing the docking station — If the transmitter is to be installed in a Zone 2 explosion-hazard area, select a lo- cation with low exposure to mechanical risk. With its exceptional electromagnetic compatibility and a variety of mounting options, the CE marked Polytron is suitable for many different areas of ppolytron ranging from chemical deager the semiconductor industries.

Key Features Simple, quick installation Wide range of applications Easy to operate and maintain. Maintenance Calibrating the zero point For all sensors except oxygen sensor: You can use the robust and long-life Splash guard 68 07 Splash guard AC sensor 68 09 Page 52 UL approval Page 27 ATEX approval Page 50 IECEx approval Calibration bottle Polygron the calibration of electrochemical sensors not type AC.

Drager – Polytron

Digital temperature compensation of the sensor signal is automatically performed. Maintenance Calibrating the zero point For all sensors except oxygen sensor: Don’t show me this message polygron. See our Privacy Notice.

work_outlinePosted in Love